Login to Recieve Online Results Return to S-F Analytical Labs Homepage
 
 

Home | Testing Services | Environmental Testing

For more information: email the department manager or please call (262) 754-5300 ext. 1405.

Our laboratory analyzes a variety of environmental sample matrices for investigation, compliance, and research and development purposes.

.

Our chemists have the knowledge and experience to assist you in understanding your requirements and interpreting your results.

.

They are always available to directly answer your questions.

.

SF Labs' EWS(Environmental Water Systems

.

Water Kits are a convenient way to test your water! The kit contains sampling instructions and an easy checklist of which chemicals and/or bacteria you want tested.  The list includes:

.

Coli form bacteria *
Sulfate *
Nitrate & Nitrite/Nitrogen *
Alkalinity *
pH *
Sodium *
Arsenic *
Iron *
Total Hardness *
Manganese *
Electrical Conductance & Total Dissolved Solids *
Volatile Organic Compounds (VOC's)
Mercury *
Herbicides
Lead *
Pesticide Scan and PCB's
Fluoride *
Iron/Sulfur bacteria
Chloride *
Specific Elements/Metals (ppm) call for list

.

                                                     * included in Water Test Package Price

The SF Labs Water Test kit has options for you. You can buy a package of 12 chemical tests and 1bacteria.  Or if you choose only certain tests, we have our "Pick List"; the majority of prices are $25 - $40 per test.  However, more complex tests (such as VOC, Hericides, Pesticides and PCB's) are $185-$250.  We can customize the Kit to fit your needs.  Please contact us at 800-300-6700. for details, or simply click on "Contact Us" and complete the form.

Sampling/Courier Services

.

Whether you need a sample pickup or require obtaining the actual sample,
S-F Analytical can help you. Our field technicians are equipped with the state-of-the-art meters and devices to obtain either a grab sample or 24 hour flow proportional composite sample. We also have procedures to sample in confined spaces, if required.

.

We have weekly routes in southeastern Wisconsin. Arrangements will be made for pickup in this area. We also use a courier service that will pick up or deliver anywhere in the State of Wisconsin.

Sample submission via commercial courier should be sent to:

S-F Analytical Laboratories
2345 S 170th Street

New Berlin, WI 53151

.

Sample storage after analysis

.

When sample quantity allows, portions will be retained for a period of thirty (30) days following the reporting of results for food samples, and thirty (30) days for environmental samples. If your sample needs to be retained for periods longer than this, or returned to you, please inform us upon sample delivery, so that the special arrangements can be made.

Partial List Of Tests:


Wet Chemistry
Method
Metals
Method
Alkalinity
BOD5
COD
Chloride
Total Hardness
Chlorine
Hexavalent Chromium
Conductivity
Cyanide
Fluoride
Ammonia
Total Kjeldahl Nitrogen
Nitrates (NO3+NO2)
Nitrite
Oil & Grease gravimetric
Oil & Grease(Hexane)
Oil & Grease(TRO&G)
Oil & Grease(TRPH)
pH
Phenols
Orthophosphate
Dissolved Oxygen
Phosphorus
Total Suspended Solids
Total Solids
Total Dissolved Solids
Silica
Sulfate
Sulfide
Turbidity
EPA 310.1
SM 5210B EPA 410.4
EPA 300.0
EPA 130.2
EPA 330.3,330.5
SM 3500-CR D
EPA 120.1
EPA 335.1,335.2
EPA 300.0
EPA 350.1
EPA 351.2
EPA 300.0
EPA 300.0
EPA 413.1
EPA 1664A
EPA 413.2
EPA 418.1
EPA 150.1
EPA 420.1
EPA 365.2,300.0
EPA 360.2
EPA 365.2
EPA 160.2
EPA 160.3
EPA 160.1
EPA 370.1
EPA 300.0
EPA 376.1
EPA 180.1
Aluminum
Antimony
Arsenic
Barium
Beryllium
Boron
Cadmium
Calcium
Chromium
Cobalt
Copper
Copper (SDWA)
Iron
Lead
Lead (SDWA)
Magnesium
Manganese
Mercury
Molybdenum
Nickel
Potassium
Selenium
Silver
Sodium
Thallium
Tin
Titanium
Zinc
EPA 6010C, SM3113B
EPA 6010C, SM3113B
EPA 6010C, SM3113B
EPA 6010C
EPA 6010C
EPA 6010C
EPA 6010C, SM3113B
EPA 6010C
EPA 6010C, SM3113B
EPA 6010C
EPA 6010C, SM3113B, & SM3111B
EPA SM3111B
EPA 6010C, SM3111B
EPA 6010C, SM3113B
EPA SM3113B
EPA 6010C
EPA 6010C
EPA 245.1
EPA 6010C
EPA 6010C, SM3113B
EPA 6010C
EPA 6010C, SM3113B
EPA SM3111B
EPA 6010C
EPA 6010C, SM3113B
EPA 6010C
EPA 6010C
EPA 6010C, SM3113B
-Back to top

Parameter
Reference
Cyanide, Ammenable
Cyanide, Free
Cyanide, Reactive
Cyanide, Total
Flash Point (Pensky-Martins)
Flash Point (Setaflash)
Free Liquids (Paint Filter Liquids Test)
PCB's
Protocol A
Protocol B
SPLP
Sulfide, Reactive
Sulfide, Total
TCLP
TOC
TOX
TRPH
Total Metals
Total Solids
pH
9010
Standard Methods
SW846
9010
1010
1020
9095A
8082
CWM
CWM
1312
SW846
9030
1311



6010&7471

9040B
-Back to top

Whether you need a sample pickup or require obtaining the actual sample, S-F Analytical can help you. Our field technicians are equipped with the state-of-the-art meters and devices to obtain either a grab sample or 24 hour flow proportional composite sample. We also have procedures to sample in confined spaces, if required.
-Back to top

S-F Analytical Laboratories knows that we must earn your business every day, and we appreciate the opportunity to serve your environmental, food, or investigative testing needs to give you timely results with integrity.

Return to S-F Analytical Labs HomepageFind Out About S-F Analytical LabsLearn About Out CapabilitiesFind Out How to Contact or Find UsSite MapLogin to Receive Online ResultsReceive a Quote